Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 17 de 17
Filter
1.
Neth Heart J ; 2024 Apr 23.
Article in English | MEDLINE | ID: mdl-38653922

ABSTRACT

BACKGROUND: During transcatheter aortic valve implantation (TAVI), secondary access is required for angiographic guidance and temporary pacing. The most commonly used secondary access sites are the femoral artery (angiographic guidance) and the femoral vein (temporary pacing). An upper extremity approach using the radial artery and an upper arm vein instead of the lower extremity approach using the femoral artery and femoral vein may reduce clinically relevant secondary access site-related bleeding complications, but robust evidence is lacking. TRIAL DESIGN: The TAVI XS trial is a multicentre, randomised, open-label clinical trial with blinded evaluation of endpoints. A total of 238 patients undergoing transfemoral TAVI will be included. The primary endpoint is the incidence of clinically relevant bleeding (i.e. Bleeding Academic Research Consortium (BARC) type 2, 3 or 5 bleeding) of the randomised secondary access site (either diagnostic or pacemaker access, or both) within 30 days after TAVI. Secondary endpoints include time to mobilisation after TAVI, duration of hospitalisation, any BARC type 2, 3 or 5 bleeding, and early safety at 30 days according to Valve Academic Research Consortium­3 criteria. CONCLUSION: The TAVI XS trial is the first randomised trial comparing an upper extremity approach to a lower extremity approach with regard to clinically relevant secondary access site-related bleeding complications. The results of this trial will provide important insights into the safety and efficacy of an upper extremity approach in patients undergoing transfemoral TAVI.

2.
J Clin Med ; 13(3)2024 Jan 23.
Article in English | MEDLINE | ID: mdl-38337345

ABSTRACT

Background The femoral vein is commonly used as a pacemaker access site during transcatheter aortic valve replacement (TAVR). Using an upper arm vein as an alternative access site potentially causes fewer bleeding complications and shorter time to mobilization. We aimed to assess the safety and efficacy of an upper arm vein as a temporary pacemaker access site during TAVR. Methods We evaluated all patients undergoing TAVR in our center between January 2020 and January 2023. Upper arm, femoral, and jugular vein pacemaker access was used in 255 (45.8%), 191 (34.3%), and 111 (19.9%) patients, respectively. Clinical outcomes were analyzed according to pacemaker access in the overall population and in a propensity-matched population involving 165 upper arm and 165 femoral vein patients. Primary endpoint was Bleeding Academic Research Consortium (BARC) type 2, 3, or 5 pacemaker access site-related bleeding. Results In the overall population, primary endpoint was lowest for upper arm, followed by femoral and jugular vein access (2.4% vs. 5.8% vs. 10.8%, p = 0.003). Time to mobilization was significantly longer (p < 0.001) in the jugular cohort compared with the other cohorts. In the propensity-matched cohort, primary endpoint showed a trend toward lower occurrence in the upper arm compared with the femoral cohort (2.4% vs. 6.1%, p = 0.10). Time to mobilization was significantly shorter (480 vs. 1140 min, p < 0.001) in the upper arm cohort, with a comparable skin-to-skin time (83 vs. 85 min, p = 0.75). Cross-over from upper arm pacemaker access was required in 17 patients (6.3% of attempted cases via an upper arm vein). Conclusions Using an upper arm vein as a temporary pacemaker access site is safe and feasible. Its use might be associated with fewer bleeding complications and shorter time to mobilization compared with the femoral vein.

3.
Article in English | MEDLINE | ID: mdl-38306632

ABSTRACT

AIMS: To compare the novel 2D multi-venc and 4D flow acquisitions with the standard 2D flow acquisition for the assessment of paravalvular regurgitation (PVR) after TAVR using cardiac magnetic resonance (CMR)-derived regurgitant fraction (RF). METHODS AND RESULTS: In this prospective study, patients underwent CMR one month after TAVR to assess PVR using 2D multi-venc and 4D flow, in addition to standard 2D flow. Scatterplots and Bland-Altman plots were used to assess correlation and visualize agreement between techniques. Reproducibility of measurements was assessed with intraclass correlation coefficients. The study included 21 patients (mean age, 80 years ± 5 [SD], 9 men). Mean RF was 11.7 ± 10.0% using standard 2D flow, 10.6 ± 7.0% using 2D multi-venc flow, and 9.6 ± 7.3% using 4D flow. There was a very strong correlation between the RFs assessed with 2D multi-venc and standard 2D flow (r = 0.88, p < 0.001), and a strong correlation between the RFs assessed with 4D flow and standard 2D flow (r = 0.74, p < 0.001). Bland-Altman plots revealed no significant bias between the RFs (2D multi-venc: 1.3%; 4D flow: 0.3%). Intra- and interobserver reproducibility for 2D multi-venc flow were 0.98 and 0.97, respectively; and 0.92 and 0.90 for 4D flow, respectively. CONCLUSION: 2D multi-venc and 4D flow produce accurate quantification of PVR after TAVR. The fast acquisition of the 2D multi-venc sequence, and the free-breathing acquisition with retrospective plane selection of the 4D flow sequence provide useful advantages in clinical practice, especially in the frail TAVR population.

4.
Eur Heart J ; 44(33): 3168-3177, 2023 09 01.
Article in English | MEDLINE | ID: mdl-37555393

ABSTRACT

AIMS: Heyde syndrome is the co-occurrence of aortic stenosis, acquired von Willebrand syndrome, and gastrointestinal bleeding. Aortic valve replacement has been demonstrated to resolve all three associated disorders. A systematic review and meta-analysis were performed to obtain best estimates of the effect of aortic valve replacement on acquired von Willebrand syndrome and gastrointestinal bleeding. METHODS AND RESULTS: A literature search was performed to identify articles on Heyde syndrome and aortic valve replacement up to 25 October 2022. Primary outcomes were the proportion of patients with recovery of acquired von Willebrand syndrome within 24 h (T1), 24-72 h (T2), 3-21 days (T3), and 4 weeks to 2 years (T4) after aortic valve replacement and the proportion of patients with cessation of gastrointestinal bleeding. Pooled proportions and risk ratios were calculated using random-effects models. Thirty-three studies (32 observational studies and one randomized controlled trial) on acquired von Willebrand syndrome (n = 1054), and 11 observational studies on gastrointestinal bleeding (n = 300) were identified. One study reported on both associated disorders (n = 6). The pooled proportion of Heyde patients with acquired von Willebrand syndrome recovery was 86% (95% CI, 79%-91%) at T1, 90% (74%-96%) at T2, 92% (84%-96%) at T3, and 87% (67%-96%) at T4. The pooled proportion of Heyde patients with gastrointestinal bleeding cessation was 73% (62%-81%). Residual aortic valve disease was associated with lower recovery rates of acquired von Willebrand syndrome (RR 0.20; 0.05-0.72; P = 0.014) and gastrointestinal bleeding (RR 0.57; 0.40-0.81; P = 0.002). CONCLUSION: Aortic valve replacement is associated with rapid recovery of the bleeding diathesis in Heyde syndrome and gastrointestinal bleeding cessation. Residual valve disease compromises clinical benefits.


Subject(s)
Angiodysplasia , Aortic Valve Stenosis , von Willebrand Diseases , Humans , Aortic Valve/surgery , Angiodysplasia/complications , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/complications , von Willebrand Diseases/complications , Gastrointestinal Hemorrhage/surgery , Gastrointestinal Hemorrhage/complications , Syndrome , von Willebrand Factor
5.
JACC Cardiovasc Imaging ; 16(3): 332-341, 2023 03.
Article in English | MEDLINE | ID: mdl-36889849

ABSTRACT

BACKGROUND: Left ventricular ejection fraction (LVEF) demonstrates limited prognostic value for post-transcatheter aortic valve replacement (TAVR) outcomes. Evidence regarding the potential role of left ventricular global longitudinal strain (LV-GLS) in this setting is inconsistent. OBJECTIVES: The aim of this systematic review and meta-analysis of aggregated data was to evaluate the prognostic value of preprocedural LV-GLS for post-TAVR-related morbidity and mortality. METHODS: The authors searched PubMed, Embase, and Web of Science for studies investigating the association between preprocedural 2-dimensional speckle-tracking-derived LV-GLS and post-TAVR clinical outcomes. An inversely weighted random effects meta-analysis was adopted to investigate the association between LV-GLS vs primary (ie, all-cause mortality) and secondary (ie, major cardiovascular events [MACE]) post-TAVR outcomes. RESULTS: Of the 1,130 identified records, 12 were eligible, all of which had a low-to-moderate risk of bias (Newcastle-Ottawa scale). On average, 2,049 patients demonstrated preserved LVEF (52.6% ± 1.7%), but impaired LV-GLS (-13.6% ± 0.6%). Patients with a lower LV-GLS had a higher all-cause mortality (pooled HR: 2.01; 95% CI: 1.59-2.55) and MACE (pooled odds ratio [OR]: 1.26; 95% CI: 1.08-1.47) risk compared with patients with higher LV-GLS. In addition, each percentage point decrease of LV-GLS (ie, toward 0%) was associated with an increased mortality (HR: 1.06; 95% CI: 1.04-1.08) and MACE risk (OR: 1.08; 95% CI: 1.01-1.15). CONCLUSIONS: Preprocedural LV-GLS was significantly associated with post-TAVR morbidity and mortality. This suggests a potential clinically important role of pre-TAVR evaluation of LV-GLS for risk stratification of patients with severe aortic stenosis. (Prognostic value of left ventricular global longitudinal strain in patients with aortic stenosis undergoing Transcatheter Aortic Valve Implantation: a meta-analysis; CRD42021289626).


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Ventricular Dysfunction, Left , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Ventricular Function, Left , Prognosis , Stroke Volume , Global Longitudinal Strain , Retrospective Studies , Predictive Value of Tests , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery
6.
Eur Heart J Cardiovasc Imaging ; 24(8): 1072-1081, 2023 07 24.
Article in English | MEDLINE | ID: mdl-36915984

ABSTRACT

AIMS: Paravalvular regurgitation (PVR) is a common complication after transcatheter aortic valve replacement (TAVR) that poses an increased risk of rehospitalization for heart failure and mortality. The aim of this study was to assess the accuracy of haemodynamic indices to predict relevant PVR. METHODS AND RESULTS: In this prospective single-centre clinical trial, four haemodynamic indices of PVR measured during TAVR were assessed for their correlation with gold standard cardiac magnetic resonance (CMR)-derived regurgitant fraction (CMR-RF) at 1 month follow-up: diastolic delta (DD), heart rate-adjusted diastolic delta (HR-DD), aortic regurgitation index (ARI), and aortic regurgitation index ratio (ARI ratio). These haemodynamic indices were analysed for their ability to predict relevant PVR (defined as CMR-RF > 20%) using receiver operating characteristic (ROC) curves with corresponding area under the ROC curves (AUCs). A total of 77 patients were included and had CMR performed 41 ± 14 days after TAVR. Mean CMR-RF was 12.4 ± 9.3%. Fifteen (19.5%) patients had CMR-RF > 20%. DD had the best correlation with CMR-RF and the highest AUC to predict relevant PVR (0.82; 95% CI, 0.72-0.92), followed by HR-DD (AUC 0.78; 95% CI, 0.67-0.89), ARI (AUC 0.78; 95% CI, 0.66-0.89), and ARI ratio (AUC 0.65; 95% CI, 0.49-0.81). The optimal cut-off value for DD was 32 mmHg, with sensitivity of 69% and specificity of 77% in predicting relevant PVR. CONCLUSION: DD measured during TAVR best predicts relevant PVR. Correction for heart rate (HR-DD) or systolic blood pressure (ARI, ARI ratio) did not improve this predictive value.


Subject(s)
Aortic Valve Insufficiency , Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Insufficiency/diagnostic imaging , Aortic Valve Insufficiency/etiology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/complications , Heart Valve Prosthesis/adverse effects , Magnetic Resonance Spectroscopy/adverse effects , Prospective Studies , Severity of Illness Index , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome
7.
J Interv Cardiol ; 2022: 7245384, 2022.
Article in English | MEDLINE | ID: mdl-36189196

ABSTRACT

Background: If surgical revascularization is not feasible, high-risk PCI is a viable option for patients with complex coronary artery disease. Venoarterial extracorporeal membrane oxygenation (VA-ECMO) provides hemodynamic support in patients with a high risk for periprocedural cardiogenic shock. Objective: This study aims to provide data about short-term outcomes of elective high-risk PCI with ECMO support. Methods: A retrospective single-center registry was performed on patients with high-risk PCI receiving VA-ECMO support. The short-term outcome was defined as the incidence of major adverse cardiac events (MACE) during the hospital stay and within 60 days after discharge. Results: Between January 2020 and December 2021, 14 patients underwent high-risk PCI with ECMO support. The mean age was 66.5 (±2.5) and the majority was male (71.4%) with a mean left ventricular ejection fraction of 33% (±3.0). Complexity indexes were high (STS-PROM risk score: 2.9 (IQR 1.5-5.8), SYNTAX score I: 35.5 (±2.0), SYNTAX score II (PCI): 49.8 (±3.2)). Femoral artery ECMO cannulation was performed in 13 patients (92.9%) requiring additional antegrade femoral artery cannula in one patient because of periprocedural limb ischemia. The mean duration of the ECMO run was 151 (±32) minutes. One patient required prolonged ECMO support and was weaned after 2 days. Successful revascularization was achieved in 13 patients (92.8%). Procedural success was achieved in 12 patients (85.7%) due to one unsuccessful revascularization and one procedural death. MACE during hospital stay occurred in 4 patients (28.6%) and within 60 days after discharge in 2 patients (16.7%). Conclusion: High-risk PCI with hemodynamic support using VA-ECMO is a feasible treatment option, if surgical revascularization is considered very high risk. Larger and prospective studies are awaited to confirm the benefits of ECMO support in elective high-risk PCI comparing ECMO with other mechanical circulatory support devices, including coaxial left cardiac support devices and IABP. Trial Registration. This trial is registered with NCT05387902.


Subject(s)
Extracorporeal Membrane Oxygenation , Percutaneous Coronary Intervention , Aged , Female , Humans , Male , Prospective Studies , Registries , Retrospective Studies , Shock, Cardiogenic/surgery , Stroke Volume , Ventricular Function, Left
8.
Circ Cardiovasc Interv ; 15(7): e011848, 2022 07.
Article in English | MEDLINE | ID: mdl-35861798

ABSTRACT

BACKGROUND: Heyde syndrome is the co-occurrence of aortic stenosis and gastrointestinal bleeding secondary to angiodysplasias. Surgical aortic valve replacement effectively reduces bleeding, but the effects of transcatheter aortic valve implantation (TAVI) are largely unknown. This study aimed to describe the reduction of gastrointestinal bleeding in patients with Heyde syndrome after TAVI and to identify the factors associated with rebleeding. METHODS: We enrolled patients with Heyde syndrome from a prospective TAVI registry. Gastrointestinal bleeding episodes were assessed by the Bleeding Academic Research Consortium classification, and cumulative incidence functions were used to calculate cessation rates. Factors potentially associated with rebleeding were analyzed using logistic regression. Differences between Heyde and non-Heyde patients were assessed through a case-cohort study. RESULTS: Between December 2008 and June 2020, 1111 patients underwent TAVI. There were 70 patients with Heyde syndrome (6.3%). In the first year following TAVI, gastrointestinal bleeding ceased in 46 of 70 patients (62% [95% CI, 50%-74%]). Bleeding episodes decreased from 3.2 (95% CI, 2.5-4.2) to 1.6 ([95% CI, 1.2-2.2] P=0.001) and hemoglobin levels increased from 10.3 (95% CI, 10.0-10.8) to 11.3 (95% CI, 10.8-11.6) g/dL (P=0.007). Between 1 and 5 years after TAVI (35 [interquartile range, 21-51] months), 53 of 62 patients (83% [95% CI, 72%-92%]) no longer experienced gastrointestinal bleeding. Paravalvular leakage (≥mild) was associated with rebleeding risk (odds ratio, 3.65 [95% CI, 1.36-9.80]; P=0.010). Periprocedural bleeding was more common in Heyde than in control patients (adjusted odds ratio, 2.55 [95% CI, 1.37-4.73]; P=0.003). CONCLUSIONS: Patients with Heyde syndrome are at increased risk for periprocedural bleeding. Post-TAVI, gastrointestinal bleeding disappears in the majority of patients. Paravalvular leakage may curtail these clinical benefits.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis Implantation , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/complications , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Cohort Studies , Gastrointestinal Hemorrhage/diagnosis , Gastrointestinal Hemorrhage/etiology , Gastrointestinal Hemorrhage/therapy , Heart Valve Prosthesis Implantation/adverse effects , Humans , Prospective Studies , Risk Factors , Syndrome , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
9.
J Card Surg ; 36(1): 48-55, 2021 Jan.
Article in English | MEDLINE | ID: mdl-33084121

ABSTRACT

BACKGROUND AND AIM OF THE STUDY: The coronavirus disease 2019 (COVID-19) pandemic has put an enormous strain on healthcare systems and intensive care unit (ICU) capacity, leading to suspension of most elective procedures, including transcatheter aortic valve replacement (TAVR). However, deferment of TAVR is associated with significant wait-time mortality in patients with severe aortic valve stenosis. Conversely, there is currently no data available regarding the safety and feasibility of a continued TAVR program during this unprecedented crisis. The aim of this study is to evaluate the safety and feasibility of patients undergoing TAVR during the COVID-19 pandemic in our center, with specific emphasis on COVID-19 related outcomes. METHODS: All patients who underwent TAVR in our center between February 27, 2020, and June 30, 2020, were evaluated. Clinical outcomes were described in terms of Valve Academic Research Consortium 2 definitions. Patient follow-up was done by chart review and telephone survey. RESULTS: A total of 71 patients have undergone TAVR during the study period. Median age was 80 years, 63% were men, and 25% were inpatients. Procedural success was 99%. After TAVR, 30% involved admission to the ICU, and 94% were ultimately discharged to the cardiac care unit on the same day. Two patients (3%) had confirmed COVID-19 a few days after TAVR, and both died of COVID-19 pneumonia within 2 weeks after hospital discharge. CONCLUSIONS: A continued TAVR program during the COVID-19 pandemic is feasible despite limited hospital resources. However, COVID-19 related mortality after TAVR is of concern.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , COVID-19/epidemiology , Pandemics , SARS-CoV-2 , Transcatheter Aortic Valve Replacement/methods , Aged , Aged, 80 and over , Aortic Valve Stenosis/epidemiology , Comorbidity , Female , Humans , Male , Netherlands , Retrospective Studies , Treatment Outcome
10.
J Thorac Cardiovasc Surg ; 161(6): 2095-2102.e3, 2021 06.
Article in English | MEDLINE | ID: mdl-32241615

ABSTRACT

OBJECTIVES: Transcatheter aortic valve implantation (TAVI) has emerged as the preferred management strategy for elderly patients with severe symptomatic aortic valve stenosis. These patients are often at high risk of postoperative delirium (POD), which is associated with morbidity and mortality. Since POD may be prevented in a considerable part of these patients, identification of patients at risk is essential. The aim of current study was to identify geriatric assessment tools associated with delirium after TAVI, and long-term mortality. METHODS: Consecutive patients were preoperatively assessed by a geriatrician between 2012 and 2017. Geriatric assessment tools consisted of cognitive, functional, mobility, and nutritional tests. POD was prospectively assessed during hospitalization after TAVI. Mortality tracking was performed by consulting municipal registries. RESULTS: A total of 511 patients were included. Median age was 80 [76-84] years, 44.8% (n = 229) were male, and 14.1% (n = 72) had a history of POD. Delirium was observed in 66 (12.9%) patients. Impaired mobility was the strongest geriatric assessment tool associated with POD (adjusted odds ratio, 2.1 [1.1-4.2], P = .028) and 2-year mortality (adjusted hazard ratio, 2.5 [1.4-4.5], P = .003). Two-year survival was reduced with more than 10% in patients with impaired mobility before TAVI (79.4% vs 91.4%, P = .013). CONCLUSIONS: This study shows that impaired mobility is currently the best single predictor for POD and 2-year mortality in high-risk patients undergoing TAVI. Prospective multicenter studies are needed to optimize and to further explore the facilitation of routine use of POD predictors in TAVI pathways of care, and subsequent preventive interventions.


Subject(s)
Delirium , Geriatric Assessment , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Delirium/diagnosis , Delirium/epidemiology , Delirium/etiology , Delirium/mortality , Female , Humans , Male , Prospective Studies , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/mortality
11.
JACC Cardiovasc Interv ; 13(21): 2453-2466, 2020 11 09.
Article in English | MEDLINE | ID: mdl-33153562

ABSTRACT

Patients who undergo transcatheter aortic valve replacement often are frail and elderly. Delirium is a frequently observed complication, associated with impaired recovery, prolonged hospital stay, and mortality. In different hospital settings, interventions that reduced the incidence of delirium resulted in improved clinical outcome and reduced costs. In that context, prevention, early recognition, and timely interventions could be the next step toward better outcomes of transcatheter aortic valve replacement. This review is focused on awareness and recognition of delirium, including predisposing "vulnerability" factors (such as cognitive impairment and carotid artery disease) and "trigger" factors (such as anesthesia, hemodynamic imbalance, and complications). For prevention and treatment, clinicians should focus on sleep hygiene, orientation, pain management, and early mobilization. In case of delirium, a thorough search and treatment of trigger factors is warranted. Future studies should focus on risk assessment, preventive and therapeutic interventions, and their potential benefit in terms of costs and clinical outcomes.


Subject(s)
Aortic Valve Stenosis , Delirium , Transcatheter Aortic Valve Replacement , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Delirium/etiology , Humans , Postoperative Complications , Risk Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
13.
Eur J Emerg Med ; 27(3): 197-201, 2020 Jun.
Article in English | MEDLINE | ID: mdl-31714472

ABSTRACT

OBJECTIVE: To identify and compare manual and load-distributing band (LDB) cardiopulmonary resuscitation (CPR)-related injuries. METHODS: Retrospective observational cohort study. Adult, nontraumatic deaths with a postmortem computed tomography scan (PMCT) performed were classified into two groups: deceased after LDB CPR or after manual CPR. PMCT scans were reviewed for thoracoabdominal injuries such as fractures, pneumothorax and hemorrhage. The injuries between groups were compared. RESULTS: LDB CPR (n = 43) showed increased incidences of posterior rib fractures (53 vs 18%, P = 0.006), pneumothorax (23 vs 4%, P = 0.04) and more pericardial fluid (median 12 vs 6 mm, P = 0.002) compared with manual CPR (n = 29). Multivariable regression analysis revealed that LDB CPR was significantly associated with posterior rib fractures [odds ratio (OR) 5.37, 95% confidence interval (CI): 1.44-20.09, P = 0.01). Pneumothorax (OR 6.80, 95% CI: 0.73-62.99, P = 0.09) and the amount of pericardial fluid (OR 3.40, 95% CI: 0.20-56.32) were not significantly associated with LDB CPR. No significant difference was found for anterolateral rib fractures, sternal fractures, vertebral fractures, pleural fluid, hemothorax, hemopericardium, pneumoperitoneum, perihepatic, perisplenic and perirenal hemorrhage. CONCLUSION: Rib fractures, sternal fractures, hemothorax and hemopericardium are common CPR-related injuries. LDB CPR is significantly associated with more posterior rib fractures and a trend toward more pneumothoraces is observed when compared with manual CPR. This knowledge is important for caretakers in the case of ongoing CPR, as a pneumothorax may attribute to not achieving persistent return of spontaneous circulation, and to improve postresuscitation care of survivors.


Subject(s)
Cardiopulmonary Resuscitation , Heart Arrest , Rib Fractures , Thoracic Injuries , Adult , Humans , Retrospective Studies , Rib Fractures/diagnostic imaging , Rib Fractures/epidemiology , Rib Fractures/etiology
14.
Ann Thorac Surg ; 107(2): 546-552, 2019 02.
Article in English | MEDLINE | ID: mdl-30292844

ABSTRACT

BACKGROUND: The femoral artery is generally used as primary access for transcatheter aortic valve implantation. However, peripheral artery disease often precludes femoral access. The purpose of this study was to describe clinical outcome of transcatheter aortic valve implantation using the left axillary artery (LAA) as primary access site. METHODS: From December 2008 until June 2016, data on all consecutive patients treated with a Medtronic device through the LAA at our hospital were registered, and outcome was prospectively collected according to the updated Valve Academic Research Consortium-2 criteria. Mortality check was performed nationally. RESULTS: In total, 362 patients were included (median age 80 years [range, 76 to 84]; logistic European System for Cardiac Operative Risk Evaluation 17% ± 12%). Successful axillary access was achieved in 99%. Medtronic CoreValve (86%) and Evolut R (14% [Medtronic, Minneapolis, MN]) were implanted. Major vascular complications occurred in 5% of patients, 1% was LAA related. Life-threatening bleeding and major bleeding were observed in 2% and 10%, respectively. Additional complications were new left bundle branch blood (30%), new permanent pacemaker (11%), and stroke (1%). There were 6 procedural deaths (2%) and 19 deaths (5%) within 30 days. One-year mortality rate was 19%. CONCLUSIONS: This is the first study reporting outcome after transcatheter aortic valve implantation using the LAA as default access. We conclude that it is highly feasible and safe with low rates of major vascular complications, bleeding, and stroke.


Subject(s)
Aortic Valve Stenosis/surgery , Cardiac Catheterization/methods , Transcatheter Aortic Valve Replacement/methods , Aged , Aged, 80 and over , Aortic Valve Stenosis/diagnosis , Axillary Artery , Echocardiography, Transesophageal , Feasibility Studies , Female , Follow-Up Studies , Humans , Male , Retrospective Studies , Risk Factors , Severity of Illness Index , Treatment Outcome
15.
Catheter Cardiovasc Interv ; 93(2): 216-221, 2019 02 01.
Article in English | MEDLINE | ID: mdl-30232824

ABSTRACT

OBJECTIVES: To investigate the relative performance of treatment with a paclitaxel-eluting balloon (PEB) compared with an everolimus-eluting stent (EES) for in-stent restenosis (ISR) in patients with diabetes mellitus (DM). BACKGROUND: ISR remains a challenge in contemporary clinical practice, particularly in patients with DM. METHODS: In the multicenter randomized DARE trial, patients with BMS or DES ISR were randomized in a 1:1 fashion to treatment with a PEB or an EES. Patients underwent angiographic follow-up after 6 months. For the purpose of this analysis, the relative performance of PEB versus EES in diabetic patients was investigated. RESULTS: Of 278 patients enrolled in DARE, 88 (32%) had DM, of whom 46 were randomized to EES and 42 to PEB treatment. Of patients with DM, 48 (55%) had DES-ISR. Angiographic follow-up was available in 30 patients (72%) in the PEB group and 36 patients (78%) in the DES group. There were no differences in terms of 6-months minimal lumen diameter in diabetic patients treated with EES (1.46 ± 0.66 mm) versus PEB (1.78 ± 0.58 mm, P = 0.15). Adverse events at one year follow-up were similar in both groups, with Major Adverse Events (MAE, death, target vessel MI, or TVR) occurring in 17.4% in the EES group versus 11.9% in the PEB group, P = 0.44. CONCLUSIONS: In patients with ISR and DM, use of a PEB resulted in similar 6-months in-segment minimal lumen diameter and comparable rates of MAE. In-segment late loss at 6 months was significantly lower in the PEB arm. Although larger trials in DM patients with ISR are necessary, PEB is a promising treatment option obviating the need for additional stent implantation.


Subject(s)
Angioplasty, Balloon, Coronary/instrumentation , Cardiac Catheters , Cardiovascular Agents/administration & dosage , Coated Materials, Biocompatible , Coronary Artery Disease/therapy , Coronary Restenosis/therapy , Diabetes Mellitus , Drug-Eluting Stents , Everolimus/administration & dosage , Paclitaxel/administration & dosage , Percutaneous Coronary Intervention/instrumentation , Aged , Angioplasty, Balloon, Coronary/adverse effects , Cardiovascular Agents/adverse effects , Coronary Artery Disease/diagnostic imaging , Coronary Restenosis/diagnostic imaging , Coronary Restenosis/etiology , Diabetes Mellitus/diagnosis , Everolimus/adverse effects , Female , Humans , Male , Middle Aged , Netherlands , Paclitaxel/adverse effects , Percutaneous Coronary Intervention/adverse effects , Prospective Studies , Prosthesis Design , Risk Factors , Time Factors , Treatment Outcome
17.
JACC Cardiovasc Interv ; 11(3): 275-283, 2018 02 12.
Article in English | MEDLINE | ID: mdl-29413242

ABSTRACT

OBJECTIVES: The authors sought to evaluate the relative performance of a drug-eluting balloon (DEB) and a drug-eluting stent (DES) in patients with any (bare-metal or drug-eluting stent) in-stent restenosis (ISR). BACKGROUND: The treatment of ISR remains challenging in contemporary clinical practice. METHODS: In a multicenter randomized noninferiority trial, patients with any ISR were randomly allocated in a 1:1 fashion to treatment with a DEB (SeQuent Please paclitaxel-eluting balloon, B. Braun Melsungen, Melsungen, Germany), or a DES (XIENCE everolimus-eluting stent, Abbott Vascular, Santa Clara, California). The primary endpoint was noninferiority in terms of in-segment minimal lumen diameter (MLD) at 6-month angiographic follow-up. Secondary endpoints included angiographic parameters at 6 months and clinical follow-up up to 12 months. RESULTS: A total of 278 patients, of whom 56% had DES-ISR, were randomized at 8 sites to treatment with DEB (n = 141) or DES (n = 137). As compared with DEB, DES was associated with larger MLD and lower % stenosis immediately post-procedure (1.84 ± 0.46 vs. 1.72 ± 0.35; p = 0.018; and 26 ± 10% vs. 30 ± 10%; p = 0.03). Angiographic follow up was completed at 196 ± 53 days in 79% of patients. With respect to the primary endpoint of in-segment MLD at 6 months, DEB was noninferior to DES (DEB 1.71 ± 0.51 mm vs. DES 1.74 ± 0.61 mm; p for noninferiority <0.0001). Target vessel revascularization at 12-month follow-up was similar in both groups (DES 7.1% vs. DEB 8.8%; p = 0.65). CONCLUSIONS: In patients with ISR, treatment with DEB was noninferior compared with DES in terms of 6-month MLD. There were no differences in clinical endpoints, including target vessel revascularization up to 12 months. Therefore, use of a DEB is an attractive treatment option for in-stent restenosis, withholding the need for additional stent implantation.


Subject(s)
Angioplasty, Balloon, Coronary/instrumentation , Cardiac Catheters , Cardiovascular Agents/administration & dosage , Coated Materials, Biocompatible , Coronary Restenosis/surgery , Drug-Eluting Stents , Everolimus/administration & dosage , Paclitaxel/administration & dosage , Percutaneous Coronary Intervention/instrumentation , Aged , Angioplasty, Balloon, Coronary/adverse effects , Cardiovascular Agents/adverse effects , Coronary Angiography , Coronary Restenosis/diagnostic imaging , Coronary Restenosis/etiology , Everolimus/adverse effects , Female , Humans , Male , Middle Aged , Netherlands , Paclitaxel/adverse effects , Percutaneous Coronary Intervention/adverse effects , Prosthesis Design , Reoperation , Time Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...